Defense & Government Solutions

SCIF & Government Shielding

Specialized RF shielding and TEMPEST solutions for Sensitive Compartmented Information Facilities, government installations, and classified defense projects

ITAR Registered
ISO 9001:2015
TEMPEST Certified
ICD 705 Compliant
SCIF Solutions

Complete SCIF Shielding Systems

A Sensitive Compartmented Information Facility (SCIF) requires comprehensive RF shielding to prevent electromagnetic emissions from compromising classified information. We provide end-to-end solutions for SCIF construction and retrofit.

ICD 705 Compliant Design

All solutions meet Intelligence Community Directive 705 requirements for acoustic and RF security

TEMPEST/HERF Protection

Advanced shielding against electromagnetic emissions including HERF (Hazards of Electromagnetic Radiation to Ordnance)

Full Documentation & Certification

Complete test documentation package with certification for government approval

Request SCIF Assessment

Shielding Effectiveness

Typical SCIF performance

0 Hz - 1 GHz ≥100 dB
1 GHz - 10 GHz ≥90 dB
10 GHz - 40 GHz ≥80 dB
40 GHz - 100 GHz ≥70 dB
Our Services

Complete SCIF Construction & Shielding

From initial assessment to final certification, we provide comprehensive RF shielding services for government and defense facilities.

SCIF Design & Engineering

Custom SCIF design incorporating RF shielding requirements, HVAC integration, and ICD 705 compliance analysis.

  • Site survey & assessment
  • Shielding specification development
  • TEMPEST zone classification
  • Construction documentation

RF Shielding Installation

Professional installation of RF shielding systems including shielded panels, doors, windows, and penetration treatments.

  • Modular panel systems
  • Welded box construction
  • RF door & window shielding
  • Penetration & conduit seals

Testing & Certification

Comprehensive testing and documentation to meet government certification requirements for SCIF accreditation.

  • MIL-STD-461 testing
  • NSA 65-06 evaluation
  • IEEE 299 compliant testing
  • Certification documentation

SCIF Upgrades & Retrofit

Modernization of existing facilities to meet current TEMPEST and ICD 705 requirements.

  • Legacy system evaluation
  • Shielding enhancement
  • Infrastructure updates
  • Minimal disruption retrofit

Mobile & Temporary SCIFs

Deployable RF shielding solutions for field operations, temporary facilities, and mobile command centers.

  • Rapid deployment systems
  • Transportable enclosures
  • Vehicle-mounted solutions
  • Expeditionary rated

Maintenance & Support

Ongoing maintenance programs and emergency support to maintain SCIF certification status.

  • Annual re-testing
  • Damage repair
  • Shielding integrity monitoring
  • 24/7 emergency response
Standards & Compliance

Meet Government Security Standards

Our solutions comply with all relevant government standards and regulations for classified facility security.

ICD 705

Intelligence Community Directive for SCIF construction, accreditation, and security requirements

TEMPEST

NSA specifications for controlling compromising emanations from electronic equipment

MIL-STD-461

Military standard for electromagnetic interference characteristics of subsystems and equipment

NSA 65-06

National Security Agency specification for evaluation of RF shielding enclosures

Compliance Matrix

Standard / Requirement Shielding (dB) Test Method Our Capability
ICD 705 Type 1 SCIF ≥100 dB (1 GHz - 40 GHz) IEEE 299 / NSA 65-06 Exceeds
TEMPEST Zone 0 ≥80 dB (1 GHz - 10 GHz) NACSIM 5000 Exceeds
TEMPEST Zone 1 ≥60 dB (1 GHz - 10 GHz) NACSIM 5000 Exceeds
MIL-STD-461 CE102 As required by system MIL-STD-461 Compliant
HERF Protection Per mission requirements MIL-STD-464 Available
Components

SCIF Shielding Components

Complete range of RF shielding components for SCIF construction, all tested and certified to meet government standards.

Shielded Doors

  • • Single & double leaf
  • • Up to 100 dB attenuation
  • • RF honeycomb grilles
  • • Manual & automatic options
  • • Fire-rated models available

Shielded Windows

  • • Viewport & vision panels
  • • Up to 80 dB attenuation
  • • Multiple thickness options
  • • Custom sizes available
  • • Ballistic rated options

Modular Panels

  • • Steel & aluminum construction
  • • Modular bolt-together design
  • • Scalable configurations
  • • Surface mount or flush
  • • Pre-engineered solutions

Penetration Seals

  • • Cable penetration frames
  • • Waveguide windows
  • • Air ventilation filters
  • • Pipe & conduit seals
  • • Filtered ventilators

HVAC Filters

  • • Honeycomb waveguide vents
  • • EMI/RFI air filters
  • • Air flow management
  • • Dehumidification compatible
  • • High-airflow models

Utility Pass-Throughs

  • • Filtered power entries
  • • Signal filters (coax, fiber)
  • • Water & gas entries
  • • Emergency lighting
  • • Custom configurations

EMI Power Filters

  • • 60-400 Hz power filters
  • • Up to 100 dB attenuation
  • • Military spec filtered
  • • Single & three phase
  • • Transient protection

Testing Equipment

  • • Spectrum analyzers
  • • Signal generators
  • • Near-field probes
  • • Calibration services
  • • Leak detection kits
Security & Clearances

Trusted with Classified Work

Our personnel and facilities hold the necessary security clearances and certifications to handle classified government projects with the highest level of trust and confidentiality.

ITAR Registered

International Traffic in Arms Regulations compliant

FCL Clearance

Facility Clearance level available upon request

Personnel Clearances

Cleared professionals for classified work

NDA Capable

Non-disclosure agreements available

"We maintain strict access controls and need-to-know protocols for all classified program participation."

Certifications & Standards

ISO 9001:2015

Quality Management System

AS9100D

Aerospace Quality Management

ISO 17025

Testing Laboratory Competence

NADCAP

Special Process Certification

Government Applications

Secure Facility Solutions

Protecting classified information across a wide range of government and defense facilities.

Government Buildings

SCIF construction and RF shielding for federal buildings, intelligence agencies, and secure government offices.

  • • ICD 705 compliant construction
  • • Multi-level security zones
  • • New build & retrofit options

Defense & Military

Secure facilities for military installations, defense contractors, and aerospace programs requiring TEMPEST protection.

  • • MIL-STD-461 compliance
  • • HERF/HERP protection
  • • Mission-critical applications

Intelligence Facilities

Advanced shielding for intelligence collection, analysis, and communications facilities requiring maximum security.

  • • Top secret compartmented
  • • Signal intelligence (SIGINT)
  • • Communications security

Data Centers

Secure data processing facilities with electromagnetic protection for classified and sensitive information systems.

  • • Secure server rooms
  • • Classified computing areas
  • • Equipment shielded enclosures

Defense Healthcare

Medical facilities requiring secure communications and electromagnetic protection for defense health programs.

  • • Secure medical records
  • • Telemedicine facilities
  • • Research laboratories

Research & Development

Secure R&D facilities for classified research programs, prototyping, and technology development.

  • • Secure prototype labs
  • • Classified research spaces
  • • Technology protection
Our Process

Your SCIF Project Journey

From initial consultation to final certification, we guide you through every step of the SCIF shielding process.

1

Initial Consultation

We discuss your security requirements, facility specifications, and classification levels needed.

  • Requirements gathering
  • Facility assessment
  • NDA execution
2

Engineering & Design

Our engineers develop detailed specifications and shielding designs for your facility.

  • Shielding calculations
  • System design
  • ICD 705 review
3

Installation

Professional installation by cleared technicians with full quality control documentation.

  • Expert installation
  • Quality checkpoints
  • Progress reporting
4

Testing & Certification

Comprehensive testing with full documentation package for government accreditation.

  • IEEE 299 testing
  • Documentation package
  • Certification support
FAQ

Common Questions

Answers to frequently asked questions about SCIF construction and government RF shielding.

Need More Information?

Our security-cleared team is ready to discuss your classified requirements.

Contact Our Team
Classified Projects Welcome

Ready to Discuss Your SCIF Requirements?

Our government solutions team is ready to help with your classified facility requirements. Contact us for a confidential consultation.

ICD 705 Experts

Full compliance consultation

Cleared Personnel

Security-cleared team

NDA Available

Protect your information

For classified requirements, please indicate your security level and we will connect you with appropriate cleared personnel.

[email protected] | Response within 24 hours